• Service
  • Resources
    • Webinars
    • Upcoming Events
    • Documents Download
    • FAQ
    • NMPA Approval Report
  • News
  • CER
  • About
Subscribe

Our Services

Strategy Consulting

  • Market Entry Strategy
  • Regulatory Strategy
  • Clinical Strategy
  • China Localization Strategy
  • Hainan Urgent Use Pathway
  • Innovation Pathway
  • Fast Track Pathway
  • Digital Health Consulting

Registration Affairs

  • Pre-market Registration
  • Modification Registration
  • Renewal Registration
  • Request for Classification
  • Legal Agent Representation
  • NMPA Expert Panel Meeting
  • NMPA Supplemental Notice

Quality Assurance

  • Postmarket Surveillance Compliance (IFU, Label, GSP)
  • Adverse Event Reporting
  • Recall Handling
  • Periodic Risk Evaluation Report
  • Annual QMS Self-Inspection Report
  • NMPA Inspections & Mock-Audit
  • QMS Establishment/Audit/Remediation
  • QA Gap Analysis
  • Factory Audit
  • Unique Device Identifier

Device Testing

  • China Local Type Testing
  • Device Modification Compliance Testing
  • Biocompatibility Testing
  • EMC Testing

Clinical Research Organization (CRO)

  • Clinical Trials/Research
  • Real-World Study
  • China CER & MDR CER
  • Clinical Evaluation Feasibility Assessment

Customized Training

  • China Regulatory Training
  • China QMS Training
  • China GCP Training
  • China Localization Training
  • Periodic Regulatory Updates Training

Other Services

  • Translation
  • Patent & Trademark
  • Distributor Evaluation & Audit
  • KOL Interview/Consultation
  • Investment
  • Global regulatory services
  • Service
  • Resources
    • Resources
    • Webinars
    • Upcoming Events
    • Documents Download
    • FAQ
    • NMPA Approval Report
  • News
  • About
  • CER
  • Subscribe
  • CN
  • US
  • Home
  • FAQ
  • Non-active Device

FAQ


  • FAQ
  • Active Device
  • Non-active Device
  • IVD
  • HGRAC
  • Clinical Evaluation
  • Common FAQ
  • What Are The Principles For Establishing Acceptance Criteria For Ethylene Oxide Residuals In Products Such As Suture Anchor, Titanium Plate With Loop?

    If suture anchor, titanium plate with loop etc. are sterilized with ethylene oxide, acceptance criteria for ethylene oxide residuals should be established. The intended use and structure & composition of the product should be combined to fully consider the effect of ethylene oxide residuals on safety and effectiveness of product. Refer to GB/T 16886.7, to explain the process of establishing the acceptance criteria.

    READ MORE >

  • How Should The Declared Special Properties Of Infusion Products Be Verified?

     In addition to developing the corresponding physical and chemical requirements in product technical requirements according to the product characteristics, the administrative counterpart should also simulate the actual clinical use conditions to verify the declared special properties. The verification test should at least consider product design, intended use, use method, service life and other aspects so as to develop the test method suitable for the product under application based on product characteristics. In the process of developing a test protocol, at least the following should be considered:

    1. The test procedure should be consistent with actual clinical practice;
    2. The selection of test conditions should cover the situations that may be involved in the clinical settings;
    3. The sample size should be able to reflect the scientific of test;
    4. The number of verification should be more than the number of uses declared for the product;
    5. Other relevant guidance documents, etc.

    READ MORE >

  • What Contents Should Be Included At Least In The Device Characteristic Description On The Product Structure And Design Of Dental Implant?

    The device characteristic description on the product structure and design of dental implant should at least include the following:

    1. Implant shape, specific nominal values and tolerances of length and diameter (e.g. body diameter and platform diameter);
    2. Macroscopic design parameters of threads (e.g. single­thread, double-thread, triple-thread). Geometric parameters of thread unit, include thread shapes (e.g. V-shaped, rectangle, saw tooth, buttress thread, reverse-buttress thread, and square), thread pitch and thread depth;
    3. Implant neck characteristics (e.g. bone level, soft tissue level);
    4. Contour design of implant apex region (e.g. blunt, sharp, cylindrical, conical) and apex region thread angle (e.g. symmetrical, upper flat and lower taper, upper taper and lower flat);
    5. Implant-abutment connection type (e.g. internal hexagon connection, external octagon connection and Morse taper connection);
    6. Axial plane characteristics of the implant (e.g. axial anti­rotation groove);
    7. Platform switching design (if any);
    8. Other structure and design characteristics specific to the product under application.

    READ MORE >

  • What Should Be Focus Of The Performance Studies Of PMMA Bone Cement Products At Least?

    The performance studies of PMMA bone cement products should focus on the performance studies of powders and liquids, and the performance studies of the final product after mixing the powders and liquids, including but not limited to the following:

    1. Study on the components and ratios of the powder and liquid, the morphology and particle size distribution of the powder components;
    2. Molecular weight, such as viscosity-average molecular weight, number-average molecular weight/weight-average molecular weight;
    3. Polymer structure, such as graft, linear or copolymerization;
    4. Physical properties, such as porosity, shrinkage, water absorption, etc.;
    5. The stability of components, such as aging caused by liquid absorption and polymerization, changes in liquid viscosity after being heated, changes (aging) in benzoyl peroxide;
    6. Evaluation of monomer residues, such as the amount of monomers precipitated during and after polymerization, the amount of residual monomers after polymerization, and the safety evaluation of monomer residues toxicity;
    7. The study of dynamic and static mechanical properties of product considering the applicable site of patients;
    8. Study on the polymerization of powder and liquid mixture of PMMA bone cement during the intended use.

    READ MORE >

  • As For Implantable Medical Devices Which Are Degradable And Absorbable, Can Published Literature By Research Institutions Related To The Products Made Of The Same Material Or The Raw Material Of The Product Under Application Be Used As The Performance Research Data On Product Degradation?

    As for implantable medical devices which are degradable and absorbable, if relevant published literature by research institutions is intended to be used as the performance research data on product degradation, the difference between the products or materials in the literature and the product under application should be analyzed to determine its effect on the evaluation result of degradation performance. Generally, a degradation study includes studies of degradation products and degradation period. For a study on degradation period, if the published literature is not related to the product under application, it will have limited value for reference, because the degradation period of products is correlated with the performance parameters (e.g. molecular weight, distribution of molecular weight, crystallinity and etc. of a polymer) and the manufacturing process of the component materials of products. In this case, administrative counterparts are recommended to conduct experimental studies on degradation period of the product under application. For metabolism studies on degradation products, if the degradation products for the devices or raw materials in the literature are the same with those of the product under application, then the research data in literature on metabolism of degradation products can be referred. And the administrative counterpart may submit the related literature and analyze the effects of different implantation sites (if involved) on

    ...

    READ MORE >

  • Which Surface Performance Studies Should Be Conducted For The Dental Implant With Sandblasted And Acid-etched Surface At Least?

    Surface treatment with sand-blasting and acid-etching is one of the methods for surface modification of dental implants and is also an important factor affecting implant osseointegration. The dental implant with sandblasted and acid-etched surface should be subject to a comprehensive study on surface performance, which should at least include the following: clarifying the sand-blasting particles as well as the particle size and particle size distribution of the sand-blasting particles, and providing the basis for setting various parameters (e.g. sand-blasting pressure, time, sand-blasting speed, angle and distance, etc.) during sand-blasting; clarifying the composition of acid etchant and the ratio thereof (volume ratio or mass ratio), and providing the basis for determining the composition ratio of acid etchants, acid­etching time and conditions; providing the high-resolution product surface drawing after surface treatment and indicating the models of relevant test instruments and equipment used; and providing the analysis data of product surface morphology under electron microscope at different scale of magnifications, which should include quantitative and qualitative analysis, such as analysis on the number and distribution of Class I and II cavities.

    READ MORE >

  • What Are The Interests In The Review Of Metallic Powder Materials For Additive Manufacturing In Dentistry?

    The technical review of metallic powder materials for additive manufacturing in dentistry mainly focus on three aspects: the performance requirements of metallic powder for additive manufacturing in dentistry, the process parameter validation of additive manufacturing and the performance of printed test pieces after additive manufacturing and forming. The performance requirements of metallic powder for additive manufacturing in dentistry include but not limited chemical composition (oxygen, hydrogen and impurity elements), sphericity, powder particle size and size distribution, flowability, apparent density, and tap density. For process parameter validation of additive manufacturing, it is necessary to clarify the printing parameters of the printing equipment and printing equipment systems compatible with the product, including but not limited to laser power, spot diameter, scanning interval, powder spreading thickness and scanning speed. In addition, it is necessary to submit the validation and verification report on various parameters and specify the relevant parameters in product technical requirements (PTR) and instructions for use (IFU). The performance requirements for the printed test piece after additive manufacturing and forming include the verification of the mechanical strength of the printed test piece in each direction, which should simulate as far as possible the actual use of the dental restorations in clinical application, with its fat

    ...

    READ MORE >

  • Can The Extraction Limit Of Soft Corneal Contact Lenses Determined Based On The Extraction Study Report Of The Same Kind Or Similar Products Be Submitted?

     It is recommended to submit the extraction study report for the product under application, clarifying the extraction method and the basis for determining the extraction limit. If the extraction study report of products of the same kind or similar products is submitted as the basis for such determination, it is recommended to select products with similar formulation, e.g., those only with differences in content of color additives. It is not recommended to select products with significant differences with the product under application in formulation. It is also recommended to describe the similarities and differences between the selected products and the product under application and demonstrate that such selected products are representative, which can be discussed from raw material formulation, dry weight of both products, recommended wearing period, etc., and analyze whether the differences affect the results of extraction study. Attention should be given to the rationality of the upper limit of extraction rate.

    READ MORE >

  • How To Evaluate The Safety Of DEHP In Single Use Hemodialysis Tubing Made Of PVC Raw Materials Plasticized By DEHP?

     When evaluate the safety of DEHP, suitable extraction solution (e.g. ethanol water) and test method should be adopted to detect the total amount of DEHP extractable in the product by using the tubing set with the highest DEHP content and simulating the most stringent clinical usage conditions (e.g. reference to the method of preparing test solution for chemical performance as specified in YY 0267, a flow rate of 200 mL/min or the maximum blood flow rate declared for the product in clinical use, circulation at 37°C for 5.5 hours). At the same time, the toxicity analysis, safety limit of human blood exposure to DEHP and the corresponding source basis should be provided, and intended population with different body weights should be evaluated respectively concerning their physiological characteristics for the safety of DEHP

    READ MORE >

  • Should The Mode Of Connection Between Dental Implant And Abutment Fall Under Product Structure And Components?

    Yes. The mode of connection between dental implant and abutment is among the contents that should be specified in the product structure and components. The modes of implant-abutment connection is mainly classified into external and internal connection types, and can also be classified into internal square connection, external hex connection, external octagon connection, internal hexagon connection and Morse taper connection by geometric shapes. Based on different modes of connection, the administrative counterpart should respectively carry out the relevant studies on the verification of system compatibility such as the taper fit of internal connection of the implant, the fit clearance between the implant and the abutment, the torsional property, the tightening torque and the fatigue limits.

    READ MORE >

  • Should Manufacturer Take The Oxygen Permeation Properties Into Consideration When Changing The Center Thickness Of Soft Contact Lenses?

    Yes. The oxygen permeation properties of soft contact lenses include two indexes: oxygen permeability Dk and oxygen transmissibility Dk/t, and the latter is directly related to the thickness of the lens. Therefore, when changing the center thickness of the lens, the manufacturer should consider the effect of the change in thickness on properties of the lens to note whether the change in thickness has led to changed nominal value of the oxygen transmissibility Dk/t. If it is necessary to modify such nominal value, the administrative counterpart should submit corresponding test report as supporting data, as well as the basis for determining such nominal value of oxygen transmissibility Dk/t. Meanwhile, the relevant risk analysis should be conducted and verification data should be provided as needed.

    READ MORE >

  • What Aspects Should Be Considerded In Registration Submission When Multiple Receiving Coils In MRI System Are Used Jointly?

    In the case of joint use of multiple receiving coils in the MRI system, the following issues shall be considered in the registration submission:

    1. The combination mode, patient positioning mode and corresponding scanning position of the coil should be described in the overview material;
    2. The performance of SNR, uniformity, 2D scanning layer thickness, spatial resolution and ghost should be provided in the research data;
    3. The product technical requirements shall include the performance requirements of single coil and the performance requirements of multi coil joint use;

    For clinical evaluation, the joint combined coil should be combined with the appropriate scanning position.

    READ MORE >

« Prev...246...1112131415...182022...Next »
Twitter Linkedin
United States
Email: info@bradyknowsmedical.com
Phone: +86 18600392020
China
Beijing Office: Room 1501-1502, East Ocean Centre, No. 24 A, Jianguomenwai Avenue, Chaoyang District, Beijing, China
Shanghai Office: Lingang New Zone, China (Shanghai) Pilot Free Trade Zone
Hainan Office: Boao Lecheng pilot zone of international medical tourism, Qionghai City, Hainan Province
Email: info@bradyknowsmedical.com
Phone: +86 18600392020 +86 10 65155991

©2025 Bradynuoen Beijing PharmTech Co Ltd All Rights Reserved.

京ICP备15042665号-7