• Service
  • Resources
    • Webinars
    • Upcoming Events
    • Documents Download
    • FAQ
    • NMPA Approval Report
  • News
  • CER
  • About
Subscribe

Our Services

Strategy Consulting

  • Market Entry Strategy
  • Regulatory Strategy
  • Clinical Strategy
  • China Localization Strategy
  • Hainan Urgent Use Pathway
  • Innovation Pathway
  • Fast Track Pathway
  • Digital Health Consulting

Registration Affairs

  • Pre-market Registration
  • Modification Registration
  • Renewal Registration
  • Request for Classification
  • Legal Agent Representation
  • NMPA Expert Panel Meeting
  • NMPA Supplemental Notice

Quality Assurance

  • Postmarket Surveillance Compliance (IFU, Label, GSP)
  • Adverse Event Reporting
  • Recall Handling
  • Periodic Risk Evaluation Report
  • Annual QMS Self-Inspection Report
  • NMPA Inspections & Mock-Audit
  • QMS Establishment/Audit/Remediation
  • QA Gap Analysis
  • Factory Audit
  • Unique Device Identifier

Device Testing

  • China Local Type Testing
  • Device Modification Compliance Testing
  • Biocompatibility Testing
  • EMC Testing

Clinical Research Organization (CRO)

  • Clinical Trials/Research
  • Real-World Study
  • China CER & MDR CER
  • Clinical Evaluation Feasibility Assessment

Customized Training

  • China Regulatory Training
  • China QMS Training
  • China GCP Training
  • China Localization Training
  • Periodic Regulatory Updates Training

Other Services

  • Translation
  • Patent & Trademark
  • Distributor Evaluation & Audit
  • KOL Interview/Consultation
  • Investment
  • Global regulatory services
  • Service
  • Resources
    • Resources
    • Webinars
    • Upcoming Events
    • Documents Download
    • FAQ
    • NMPA Approval Report
  • News
  • About
  • CER
  • Subscribe
  • CN
  • US
  • Home
  • FAQ
  • Non-active Device

FAQ


  • FAQ
  • Active Device
  • Non-active Device
  • IVD
  • HGRAC
  • Clinical Evaluation
  • Common FAQ
  • Under Which Circumstances Should The Pulp And Dentin Usage Test Be Taken Into Consideration During The Biological Evaluation Of Dental Materials?

     In the pulp and dentin usage test, the material is filled in the prepared tooth cavity of the animal. After a certain period of time, the pulp and dentin is observed for histopathologic response to evaluate the irritation of the material to the pulp-dentine complex. Generally, dental pulp irritation may occur in all usages where whole enamel and/or partial dentin are removed. Therefore, for dental materials used in such case, the pulp and dentin irritation should be taken into consideration in biological evaluation.

    For the adhesive and cement products, if the administrative counterpart regulates the product operation in the IFU, clearly requiring that “The product cannot be directly used to exposed pulp, and appropriate pulp protection measures should be used when necessary", and clinicians can effectively reduce the risks of pulp and dentin irritation reaction of such products by following the operation norms, such products may be exempted from pulp and dentin usage test.

    READ MORE >

  • Is It Necessary To Conduct Subchronic Toxicity Test For Dental Noble-metal Alloys?

    The toxicity, allergic reaction and other adverse biological reactions of dental alloys to human bodies are closely related to metal elements released into the oral cavity. The degree of biological reaction of dental alloys is affected by the nature and concentration of elements released as well as the duration of exposure to oral tissues. It is recommended to consider the biocompatibility of dental noble-metal alloys from the following aspects:

    1. The quantity, type, microstructure and composition of phases in alloy;
    2. Whether there are such elements as copper, zinc, silver, calcium and nickel;
    3. Single metal elements may be greater than alloyed metal elements;
    4. Various combinations of alloy elements in the oral cavity may change the corrosion and biocompatibility of alloys;
    5. Whether the element release level of alloy containing noble metal elements is lower than that of ordinary alloys.

    READ MORE >

  • Is Mouse Embryo Assay Required For Consumable Products For In Vitro Assisted Reproduction (except The Fluid For In Vitro Assisted Reproduction)?

     The consumables for in vitro assisted reproduction (except the fluid for in vitro assisted reproduction) act on gametes, zygotes, and embryonic cells at different developmental stages. Therefore, in addition to routine biological evaluations, in vitro mouse embryo assay should be performed with reference to YY/T 1434 for such products. Because the results of mouse embryo assay are an important indicator for evaluating the safety of such products, according to the industry requirements and requirements of clinical assisted reproduction for such products, mouse embryo assay should be used as a routine quality control item for such products.

    READ MORE >

  • Is It Possible To Use The Same Raw Materials As Those Of The Final Product For Biocompatibility Test?

    The biological evaluation of product should consider the materials used in the manufacture of the product, intended additives, process contaminants and residues, leachable substances, degradation products, physical properties of the final product, the individual components and their interactions in the final product, packaging materials and the influence of the preservation medium on biocompatibility as well as other factors, so the biocompatibility test of the product should in principle be carried out on the final product, or on the representative samples taken from the final product. If it is not feasible to use the final product for testing, it may be considered to use the specimens produced with the same processes as the final product for testing, but the representatives of the specimens needs to be fully analyzed and demonstrated.

    READ MORE >

  • If An Orthopedic Implant Made Of Pure Titanium Or Titanium Alloy Material Is Treated With Colored Anodizing, And The Surface Of The Product Contains Residual Impurity Elements In Addition To The Matrix Element, How To Perform The Biological Evaluation?

    For an orthopedic implant made of pure titanium or titanium alloy material is treated with colored anodizing, if there are additional residual impurity elements in addition to the matrix element, biological evaluation should be performed in accordance with the "Notice on Issuing the Guidelines for Biological Evaluation and Review of Medical Devices” (CFDA [2007] No. 345) and GB/T 16886 series standards to analyze the source of surface impurity elements and the reason for the introduction thereof, fully demonstrate the biological risk of the product, and meanwhile clarify the corresponding quality control measures of impurity elements in colored anodizing process.

    READ MORE >

  • In The Biocompatibility Evaluation Study Of Dressing Products, What Should Be Paid Attention To In Extract Preparation And The Selection Of Evaluation Items?

    Dressing products often need replacement during clinical use, and the product itself has a certain fluid absorption nature. Therefore, the following issues need to be addressed in biocompatibility evaluation:

    1. When preparing the extract of dressing products, the determination of the extraction time should take into account the cumulative clinical use time of the product; when determining the volume of the extraction medium, in addition to considering the extraction ratio, the volume of the extraction medium to be absorbed by the product should also be considered.
    2. For the evaluation items, the cumulative contact duration between the product and the human body should be considered, not the single contact duration.

    READ MORE >

  • If The Abutment Product Has Undergone Colored Anodizing Treatment, How To Submit The Biological Evaluation Data?

    For the abutment products which have undergone colored anodizing, it is necessary to perform biological evaluation according to the "Notice on Issuing the Guidelines for Biological Evaluation and Review of Medical Devices" (CFDA [2007] No. 345), GB/T 16886 and YY/T 0268 series standards and to perform analysis on the surface elements of product; if any impurity element other than matrix element is contained, it is necessary to analyze the source of surface impurity element and the reason for the introduction thereof, conduct full demonstration on biological risks of the product caused, and clarify the corresponding quality control process and risk prevention and control measures for colored anodizing.

    READ MORE >

  • What Are The Common Problems To Be Noted In The Subchronic Toxicity Test Section Of Biological Evaluation Report?

    For the evaluation indicators with statistical differences in the subchronic toxicity test, the test report should clarify whether the relevant differences impact on biological evaluation results and explain the reasons, analyze and determine the relationship between the relevant differences and the tested product, instead of simply listing items with statistical differences. The administrative counterpart should analyze and evaluate the abnormalities or risks indicated in the test report. In addition, it is necessary to provide the basis for the determination of the test dose and consider the safety factor for extrapolation of the dose to human beings.

    READ MORE >

  • Should All Models And Specifications Of Dialysate Concentrates Be Subjected To Stability Verification?

    Real-time stability verification data should be submitted for all models and specifications of dialysate concentrates. The verification should consider the characteristics of the product to examine the impact of the expected conditions, temperature, humidity, time and other factors of storage, transportation and packaging on the product.

    READ MORE >

  • How Should The Shelf Life Of A Dialysate Concentrate Product Be Determined? How Should The Stability Verification Studies Be Performed For Dialysate Concentrate Products?

    It is recommended to refer to the requirements for long-time testing of pharmaceutical products in “Guidelines for the Stability Test of Drug Substances and Products” in "Pharmacopoeia of the People's Republic of China" to submit the stability verification data of concentrates and determine the shelf life of the product based on the results.

    In the process of stability verification, it is necessary to observe the products of all models and packing volumes. According to the actual situation of the product, determine the appropriate conditions of the storage, transportation and packaging, and the storage condition of temperature and humidity in the south or north expected, check for the stability of the concentrate at different assessment time points.

    The observation items should include all performance in technical requirements and analysis of chemical contaminants. It is also necessary to provide the test results of such items as solute concentration, insoluble particles, microbial limit (or sterility), and endotoxin of the concentrates at different assessment time points in accordance with the technical requirements. For dry powder, the comparison result of dissolution time should be added. For the dry powder B products for online use, the test results of ion concentration and pH at four time points at least (at the beginning of dialysis, the two

    ...

    READ MORE >

  • What Data Should Be Provided At Least For Radiation Sterilization Verification Of Non-active Implant?

    For verification of radiation sterilization verification of non­active implant, it is necessary to define the radiation source and radiation dose, provide the corresponding basis for such determination, as well as the initial average bioburden test report and dose verification test report, and provide the sterility test report of product after sterilization with minimum radiation dose determined based on the initial average bioburden. The radiation sterilization validation report should include the selection of the product and packaging materials, the determination of the product loading mode, and the product dose map, etc. It should be noted that the establishment of radiation dose for sterilization should not be based on biological indicators (generally bacillus pumilus spores), but should be based on microorganisms (e.g. bacillus stearothermophilus spores) that have stronger radiation resistance loaded in sterilization articles. If the product used for sterilization verification is not the product under application, it is necessary to provide the supporting data demonstrating its equivalence to the product under application in terms of raw materials, sterilization methods, sterilization doses, packaging materials, packaging processes, packaging methods, and other factors that affect resistance to bacteria.

    READ MORE >

  • For Animal-derived Dental Biomaterials, If The Sterilization Method Is Changed, Can The Method Be Added Or Changed Through The Procedures For Change Of Permission Items?

    The sterilization method can be added or changed through the procedures for change of permission items. In case of any change in the sterilization method of animal-derived dental biomaterials, it is necessary to submit at least the sterilization effectiveness verification report and the product shelf life verification report, and to confirm whether the change in sterilization method has any influence on the safety and effectiveness of the product. If the product performance is affected by sterilization, it should be re-verified. If the sterilization process is used as the process of virus inactivation, the change in sterilization method requires re-verification of virus inactivation; if the sterilization process is not used as the process of virus inactivation, it is not necessary to re-verify virus inactivation.

    READ MORE >

« Prev...2...678910...141618...Next »
Twitter Linkedin
United States
Email: info@bradyknowsmedical.com
Phone: +86 18600392020
China
Beijing Office: Room 1501-1502, East Ocean Centre, No. 24 A, Jianguomenwai Avenue, Chaoyang District, Beijing, China
Shanghai Office: Lingang New Zone, China (Shanghai) Pilot Free Trade Zone
Hainan Office: Boao Lecheng pilot zone of international medical tourism, Qionghai City, Hainan Province
Email: info@bradyknowsmedical.com
Phone: +86 18600392020 +86 10 65155991

©2025 Bradynuoen Beijing PharmTech Co Ltd All Rights Reserved.

京ICP备15042665号-7